| Model |
MDV-D71T1/N1-B(B) |
MDV-D80T1/N1-B(B) |
MDV-D90T1/N1-B(B) |
| Power supply |
V- Ph-Hz |
220-240V~, 1Ph, 50Hz |
| Cooling |
Capacity |
kW |
7.1 |
8.0 |
9.0 |
| Input |
W |
263 |
263 |
423 |
| Rated current |
A |
1.23 |
1.23 |
1.87 |
| Heating |
Capacity |
kW |
8.0 |
9.0 |
10.0 |
| Input |
W |
263 |
263 |
423 |
| Rated current |
A |
1.23 |
1.23 |
1.87 |
| Max. input consumption |
W |
269 |
269 |
437 |
| Max. current |
A |
1.23 |
1.23 |
1.87 |
Indoor fan motor |
Model |
YDK100-4X-2 |
YDK100-4X-2 |
YDK160-4C |
| Type |
AC Motor |
| Brand |
Yong An |
Yong An |
WELLING |
| Input |
W |
240 |
240 |
375 |
| Capacitor |
μF |
12 |
12 |
10 |
| Speed (h/m/l) |
r/min |
990/940/900 |
990/940/900 |
1335/1290/1235 |
| Indoor coil |
Number of rows |
2 |
2 |
3 |
| Tube pitch(a) × row pitch(b) |
mm |
25.4×22 |
25.4×22 |
25.4×22 |
| Fin spacing |
mm |
1.5 |
1.5 |
1.6 |
| Fin type |
Hydrophilic aluminum |
Tube outside diameter and type |
mm |
Ф9.52 inner groove tube |
| length× height× width |
mm |
700×356×44 |
700×356×44 |
700×356×66 |
| Number of circuits |
3 |
3 |
7 |
| Indoor air flow (H/M/L) |
m3/h |
1443/1361/1218 |
1416/1338/1220 |
1951/1741/1518 |
| *Indoor external static pressure |
Pa |
25(25~ 196) |
37(37~ 196) |
37(37~ 196) |
| Indoor noise level (H/M/L) |
dB(A) |
48/46/44 |
48/46/44.5 |
52/49/47 |
| Indoor unit |
Dimension (W×H×D) |
mm |
952×420×690 |
952×420×690 |
952×420×690 |
| Packing (W×H×D) |
mm |
1090×440×768 |
1090×440×768 |
1090×440×768 |
| Net/Gross weight |
kg |
45/50 |
45/50 |
46.5/52.4 |
| Refrigerant type |
R410A |
| Throttle |
Type |
Electronic expansion valve |
| Model |
BD20FKS (Winding: DZF20XQ-1000-XHP-6) |
| Design pressure (H/L) |
MPa |
4.4/2.6 |
| Refrigerant piping |
Liquid / Gas |
mm |
Ф9.53/ Ф15.9 |
Ф9.53/ Ф15.9 |
Ф9.53/ Ф15.9 |
| Connecting wiring |
Power wiring |
mm2 |
3×2.5(L≤20m); 3×3.5(L≤50m) |
| Signal wiring |
mm2 |
3×0.75 |
| Drainage water pipe diameter |
OD Ф25 |
| Controller |
Wired controller KJR-29B1/BK-E (6 meters connection wire) |
| Model |
MDV-D112T1/N1-B(B) |
MDV-D140T1/N1-B(B) |
MDV-D160T1/N1-B(B) |
| Power supply |
V- Ph-Hz |
220-240V~, 1Ph, 50Hz |
| Cooling |
Capacity |
kW |
11.2 |
14 |
16 |
| Input |
W |
524 |
724 |
940 |
| Rated current |
A |
2.3 |
2.85 |
4.77 |
| Heating |
Capacity |
kW |
12.5 |
16 |
17 |
| Input |
W |
524 |
2.85 |
940 |
| Rated current |
A |
2.3 |
2.7 |
4.77 |
| Max. input consumption |
W |
528 |
724 |
940 |
| Max. current |
A |
2.3 |
2.85 |
4.77 |
Indoor fan motor |
Model |
YSK200-4F-1 |
YSK300-4C-1 |
YSK400-4C-2 |
| Type |
AC MOTOR |
| Brand |
WELLING |
YongAn |
YongAn |
| Input |
W |
490 |
720 |
930 |
| Capacitor |
μF |
15 |
12 |
15 |
| Speed (h/m/l) |
r/min |
1000/930/774 |
860/760/670 |
1080/920/850 |
| Indoor coil |
Number of rows |
3 |
4 |
4 |
Tube pitch(a) ×row pitch(b) |
mm |
25.4×22 |
25.4×22 |
25.4×22 |
| Fin spacing |
mm |
1.6 |
1.6 |
1.6 |
| Fin type |
Hydrophilic aluminum |
Tube outside diameter and type |
mm |
Ф9.52 inner groove tube |
| length× height× width |
mm |
700×356×66 |
996×355.6×88 |
996×355.6×88 |
| Number of circuits |
7 |
7 |
7 |
| Indoor air flow (H/M/L) |
m3/h |
2116/1936/1520 |
3000/2618/2226 |
3620/3044/2744 |
| *Indoor external static pressure |
Pa |
50(50~ 196) |
50(50~ 196) |
50(50~ 196) |
| Indoor noise level (H/M/L) |
dB(A) |
52/49/47 |
53/50/48 |
54/52/50 |
| Indoor unit |
Dimension (W×H×D) |
mm |
952×420×690 |
1300×420×690 |
1300×420×690 |
| Packing (W×H×D) |
mm |
1090×440×768 |
1436×450×768 |
1436×450×768 |
| Net/Gross weight |
kg |
50.6/56 |
68/70 |
70/77.5 |
| Refrigerant type |
R410A |
| Throttle |
Type |
Electronic expansion valve |
| Model |
BD20FKS, (Winding: DZF20XQ-1000-XHP-6) |
| Design pressure(H/L) |
MPa |
4.4/2.6 |
| Refrigerant piping |
Liquid / Gas |
mm |
Ф9.53/ Ф15.9 |
Ф9.53/ Ф15.9 |
Ф9.53/ Ф15.9 |
| Connecting wiring |
Power wiring |
mm2 |
3×2.5(L≤20m); 3×3.5(L≤50m) |
| Signal wiring |
mm2 |
3×0.75 |
| Drainage water pipe diameter |
OD Ф25 |
| Controller |
Wired controller KJR-29B1/BK-E (6 meters connection wire) |
| Model |
MDV-D200T1/N1-B(B) |
MDV-D250T1/N1-B(B) |
MDV-D280T1/N1-B(B) |
| Power supply |
V- Ph-Hz |
220-240V~, 1Ph, 50Hz |
| Cooling |
Capacity |
kW |
20.0 |
25.0 |
28.0 |
| Input |
W |
1516 |
1516 |
1516 |
| Rated current |
A |
8.6 |
8.6 |
8.6 |
| Heating |
Capacity |
kW |
22.5 |
26.0 |
31.5 |
| Input |
W |
1516 |
1516 |
1516 |
| Rated current |
A |
8.6 |
8.6 |
8.6 |
| Max. input consumption |
W |
1978 |
1978 |
1978 |
| Max. current |
A |
8.6 |
8.6 |
8.6 |
| Indoor fan motor |
Model |
YDK550-4X (×2) |
YDK550-4X (×2) |
YDK550-4X (×2) |
| Type |
AC Motor |
| Brand |
Man Qi Wei |
Man Qi Wei |
Man Qi Wei |
| Input |
W |
916/800/675(×2) |
916/800/675(×2) |
916/800/675(×2) |
| Capacitor |
μF |
12(×2) |
12(×2) |
15(×2) |
| Speed (h/m/l) |
r/min |
1200/1065/925(×2) |
1200/1065/925(×2) |
1200/1065/925(×2) |
| Indoor coil |
Number of rows |
4 |
4 |
4 |
| Tube pitch(a) ×row |
mm |
25.4×22 |
25.4×22 |
25.4×22 |
| Fin spacing |
mm |
1.8 |
1.8 |
1.8 |
| Fin type |
Hydrophilic aluminum |
Tube outside diameter and type |
mm |
Ф9.52 inner groove tube |
| length× height × width |
mm |
1125×508×88 |
1125×508×88 |
1125×512×88 |
| Number of circuits |
20 |
20 |
20 |
| Indoor air flow (H/M/L) |
m3/h |
4700/4100/3599 |
4700/4100/3599 |
4700/4100/3599 |
| *Indoor external static pressure |
Pa |
200(50~280) |
200(50~280) |
200(50~280) |
| Indoor noise level (H/M/L) |
dB(A) |
59/55/52 |
59/55/52 |
59/55/52 |
| Indoor unit |
Dimension (W×H×D) |
mm |
1440×505×925 |
1440×505×925 |
1440×505×925 |
| Packing (W×H×D) |
mm |
1509×550×990 |
1509×550×990 |
1509×550×990 |
| Net/Gross weight |
kg |
115/129 |
115/129 |
115/129 |
| Refrigerant type |
R410A |
| Throttle |
Type |
Electronic expansion valve (2 sets throttle boxes each unit) |
| Model |
BD24FKS(L) (Winding: PXR-6-L400-XHP6R/AMP6BL-P) |
| Design pressure(H/L) |
MPa |
4.4/2.6 |
| Refrigerant piping |
Liquid / Gas |
mm |
Ф9.53/ Ф15.9 (×2) |
Ф9.53/ Ф15.9 (×2) |
Ф9.53/ Ф15.9 (×2) |
| Connecting wiring |
Power wiring |
mm2 |
3×2.5(L≤20m); 3×3.5(L≤50m) |
| Signal wiring |
mm2 |
3×0.75 |
| Drainage water pipe diameter |
OD Ф32 |
| Controller |
Wired controller KJR-29B1/BK-E (6 meters connection wire) |
| Model |
MDV-D400T1/N1(B) |
MDV-D450T1/N1(B) |
MDV-D560T1/N1(B) |
| Power supply |
V- Ph-Hz |
220-240V~, 1Ph, 50Hz |
| Cooling |
Capacity |
kW |
40.0 |
45.0 |
56.0 |
| Input |
W |
2700 |
2700 |
3400 |
| Rated current |
A |
12.5 |
12.5 |
15.5 |
| Heating |
Capacity |
kW |
45 |
50.0 |
63.0 |
| Input |
W |
2700 |
2700 |
3400 |
| Rated current |
A |
12.5 |
12.5 |
15.5 |
| Max. input consumption |
W |
2700 |
2700 |
3400 |
| Max. current |
A |
13.5 |
13.5 |
15.5 |
| Indoor fan motor |
Model |
YDK550-4X (×3) |
YDK550-4X (×3) |
YDK600-4C (×3) |
| Type |
AC Motor |
| Brand |
Yong An |
| Input |
W |
916/800/675(×3) |
916/800/675(×3) |
1130/990/850(×3) |
| Capacitor |
μF |
15(×3) |
15(×3) |
15(×3) |
| Speed (h/m/l) |
r/min |
1200/1065/935(×3) |
1200/1065/935(×3) |
1280/1135/975(×3) |
| Indoor coil |
Number of rows |
5 |
5 |
6 |
| Tube pitch(a) × row |
mm |
21×13.37 |
21×13.37 |
21×13.37 |
| Fin spacing |
mm |
1.5 |
1.5 |
1.5 |
| Fin type |
Hydrophilic aluminum |
Tube outside diameter and type |
mm |
Ф7 Inner groove tube |
| length× height× width |
mm |
1602×588×67 |
1602×588×67 |
1602×588×67 |
| Number of circuits |
28 |
28 |
28 |
| Indoor air flow (H/M/L) |
m3/h |
7472/6072/4995 |
7472/6072/4995 |
9550/7950/6600 |
| *Indoor external static pressure |
Pa |
200(50~280) |
200(50~280) |
200(50~280) |
| Indoor noise level (H/M/L) |
dB(A) |
61/59/56 |
61/59/56 |
63/60/57 |
| Indoor unit |
Dimension (W×H×D) |
mm |
1970×668×902.5 |
1970×668×902.5 |
1970×668×902.5 |
| Packing (W×H×D) |
mm |
2095×800×964 |
2095×800×964 |
2095×800×964 |
| Net/Gross weight |
kg |
232/245 |
232/245 |
235/250 |
| Refrigerant type |
R410A |
| Throttle |
Type |
Electronic expansion valve (4 sets throttle boxes each unit) |
| Model |
BD24FKS(L) |
| Design pressure(H/L) |
MPa |
4.4/2.6 |
| Refrigerant piping |
Liquid / Gas |
mm |
Ф9.53 / Ф22.2(×2) |
Ф9.53 / Ф22.2(×2) |
Ф9.53 / Ф22.2(×2) |
| Connecting wiring |
Power wiring |
mm2 |
3×2.5(L≤20m); 3×3.5(L≤50m) |
| Signal wiring |
mm2 |
3×0.75 |
| Drainage water pipe diameter |
OD Ф32 |
| Controller |
Wired controller KJR-29B1/BK-E (6 meters connection wire) |
- Призначені для монтажу за підвісною стелею з підключенням до розгалужених воздуховодной мереж та / або високим розташуванням точок видування - до 7 м від рівня підлоги;
- Фланці повітрозабірного каналу - на задній стінці блоків;
- Можливість організувати підмішування свіжого повітря;
- Пульт дистанційного керування та фотоприймач в стандартній комплектації;
- Тиск повітря 60-150 Па в робочій точці, 196 або 280Па - максимальне.
Информация об оплате
Информация о доставке
Підвищена змочуваність теплообмінника, алюмінієві пластини якого мають спеціальне покриття з гідрофільним шаром, що забезпечує швидке видалення конденсату з внутрішнього блоку, що не дозволяє швидко утворюватися цвілі і бактерій, забезпечуючи при цьому більш ефективну роботу кондиціонера.
Блок має вбудований EXV - Електронний розширювальний клапан.
- Груповий пульт керування (центральний контролер) використовується для централізованого керування внутрішніми блоками (можна підключити до 64 внутрішніх блоків через плату-адаптер).
- Внутрішні блоки можуть бути розділені на 20 зон, кожна зона може містити не більше 64 внутрішніх блоку. Всі внутрішні блоки в одній зоні можна встановити тільки на один і той же режим. (За замовчуванням "зона не призначена для внутрішніх блоків").
- Користувачі можуть вибрати бажаний режим та температуру до розкладу на тиждень.
Режим осушення автоматично вибирає режим охолодження, заснованої на різниці між встановленою темпаратура і дійсної кімнатною температурою. Температура регулюється під час зниження вологості повітря повторюваному включенням і вимиканням режиму охолодження і тільки вентиляції. при включенні режиму осушення на ПДУ відображається «Краплинка"
Підвищена тепловіддача. У блоках використовуються теплообмінники з трубками особливої конструкції, внутрішня поверхня яких має насічки трапецієподібної форми "Innergrove cooper", що забезпечує максимально збільшену площу поверхні теплообміну. Завдяки цьому тепловіддача підвищується на 28%, знижується рівень енергоспоживання і, отже, збільшується ефективність роботи системи.
Функція температурної компенсації коректує температуру в зоні знаходження людини до комфортної, (т.к. температура повітря близько підлоги та стелі може відрізнятись на декілька градусів) шляхом додаткового підвищення / пониження темпреатури від значення заданого з ПДК. Таким чином відбувається компенсація та вирівнювання загальної температури в приміщенні. Для побутових спліт систем значення встановлено виробником і становить 2°С.
Організація подачі свіжого повітря - здійснюється окремим воздуховодом (в спліт системах з такою функцією, воздуховод має звичайно невеликий діаметр і прокладається разом з трасою) ...